Interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS) for cadmium in urine and blood: Results from the HBM4EU project

Nübler, Stefanie; López, Marta Esteban; Castaño, Argelia; Mol, Hans; Schäfer, Moritz; Haji-Abbas-Zarrabi, Karin; Bury, Daniel; Koch, Holger M.; Vaccher, Vincent; Antignac, Jean-Philippe; Dvorakova, Darina; Hajslova, Jana; Thomsen, Cathrine; Vorkamp, Katrin; Göen, Thomas
Peer reviewed, Journal article
Published version
Thumbnail
View/Open
N%C3%BCbler_2021_Int.pdf (1.223Mb)
URI
https://hdl.handle.net/11250/3008656
Date
2021
Metadata
Show full item record
Collections
  • Artikler [3776]
  • Publikasjoner fra CRIStin FHI [5984]
Original version
International Journal of Hygiene and Environmental Health. 2021, .   10.1016/j.ijheh.2021.113711
Abstract
Human biomonitoring (HBM) of cadmium is essential to assess and prevent toxic exposure. Generally, low cadmium levels in urine and blood of the general population place particularly high demands on quality assurance and control measures (QA/QC) for cadmium determination. One of the aims of the HBM4EU project is to harmonize and advance HBM in Europe. Cadmium is one of the chemicals selected as a priority substance for HBM implementation in the 30 European countries under HBM4EU. For this purpose, analytical comparability and accuracy of the analytical laboratories of participating countries was investigated in a QA/QC programme comprising interlaboratory comparison investigations (ICI) and external quality assurance schemes (EQUAS). This paper presents the evaluation process and discusses the results of four ICI/EQUAS rounds for the deter-mination of cadmium in urine and blood. The majority of the 43 participating laboratories achieved satisfactory results, although low limits of quantification were required to quantify Cd concentrations at general population exposure levels. The relative standard deviation of the participants’ results obtained from all ICI and EQUAS runs ranged from 8 to 36% for cadmium in urine and 8–28% for cadmium in blood. Applying inductively-coupled plasma mass spectrometry (ICP-MS), using an internal standard, and eliminating molybdenum oxide in-terferences was favourable for the accurate determination of cadmium in urine and blood. Furthermore, the analysis of cadmium in urine was found to have a critical point at approximately 0.05 μg/l, below which vari-ability increased and laboratory proficiency decreased. This QA/QC programme succeeded in establishing a network of laboratories with high analytical comparability and accuracy for the analysis of cadmium across 20 European countries.
Journal
International Journal of Hygiene and Environmental Health

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit